Drug Deliv Transl Res ; 13(9): 2353-2366, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36913105

RESUMO

Subcutaneous (SC) delivery is a preferred route of administration for biotherapeutics but has predominantly been limited to volumes below 3 mL. With higher volume drug formulations emerging, understanding large volume SC (LVSC) depot localization, dispersion, and impact on the SC environment has become more critical. The aim of this exploratory clinical imaging study was to assess the feasibility of magnetic resonance imaging (MRI) to identify and characterize LVSC injections and their effect on SC tissue as a function of delivery site and volume. Healthy adult subjects received incremental injections of normal saline up to 5 mL total volume in the arm and up to 10 mL in the abdomen and thigh. MRI images were acquired after each incremental SC injection. Post-image analysis was performed to correct imaging artifacts, identify depot tissue location, create 3-dimensional (3D) SC depot rendering, and estimate in vivo bolus volumes and SC tissue distention. LVSC saline depots were readily achieved, imaged using MRI, and quantified via subsequent image reconstructions. Imaging artifacts occurred under some conditions, necessitating corrections applied during image analysis. 3D renderings were created for both the depot alone and in relation to the SC tissue boundaries. LVSC depots remained predominantly within the SC tissue and expanded with increasing injection volume. Depot geometry varied across injection sites and localized physiological structure changes were observed to accommodate LVSC injection volumes. MRI is an effective means to clinically visualize LVSC depots and SC architecture allowing assessment of deposition and dispersion of injected formulations.Trial Registration: Not applicable for this exploratory clinical imaging study.


Assuntos
Imageamento por Ressonância Magnética , Adulto , Humanos , Imageamento por Ressonância Magnética/métodos , Injeções Subcutâneas
2.
Clin Transl Sci ; 15(1): 92-104, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34268888

RESUMO

Determining feasibility and tolerability of large volume viscous subcutaneous injection may enable optimized, intuitive delivery system design. A translational early feasibility clinical study examined large volume subcutaneous injection viability, tolerability, acceptability, tissue effects and depot location for ~1, 8, and 20 cP injections at volumes up to 10 ml in the abdomen and 5 ml in the thigh in 32 healthy adult subjects. A commercial syringe pump system delivered 192 randomized, constant rate (20 µl/s) injections (6/subject) with in-line injection pressure captured versus time. Deposition location was qualified via ultrasound. Tissue effects and pain tolerability were monitored through 2 hours post-injection with corresponding Likert acceptability questionnaires administered through 72 hours. All injection conditions were feasible and well-tolerated with ≥79.3% favorable subject responses for injection site appearance and sensation immediately post-injection, increasing to ≥96.8% at 24 hours. Mean subject pain measured via 100 mm visual analog scale increased at needle insertion (6.9 mm, SD 10.8), peaked during injection (26.9 mm, SD 21.7) and diminished within 10 minutes post-removal (1.9 mm, SD 4.2). Immediate injection site wheal (90.9%) and erythema (92.6%) formation was observed with progressive although incomplete resolution through 2 hours (44.6% and 11.4% remaining, respectively). Wheal resolution occurred more rapidly at lower viscosities. Most subjects (64.5%) had no preference between abdomen and thigh. Correlations between tissue effects, injection pressure and pain were weak (Pearson's rho ± 0-0.4). The large volume injections tested, 1-20 cP viscosities up to 10 ml in the abdomen and 5 ml in the thigh, are feasible with good subject acceptability and rapid resolution of tissue effects and pain.


Assuntos
Injeções Subcutâneas/efeitos adversos , Injeções Subcutâneas/métodos , Dor/etiologia , Adolescente , Adulto , Idoso , Estudos Cross-Over , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
Clin Transl Sci ; 14(3): 859-869, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33278331

RESUMO

An investigational wearable injector (WI), the BD Libertas Wearable Injector (BD Libertas is a trademark of Becton, Dickinson and Company), was evaluated in an early feasibility clinical study for functional performance, tissue effects, subject tolerability, and acceptability of 5 mL, non-Newtonian ~ 8 cP subcutaneous placebo injections in 52 healthy adult subjects of 2 age groups (18-64 years and ≥ 65 years). Randomized WI subcutaneous injections (n = 208, 4/subject) were delivered to the right and left abdomen and thigh of each subject, 50% (1 thigh and 1 abdomen) with a defined movement sequence during injection. Injector functional performance was documented. Deposition was qualified and quantified with ultrasound. Tissue effects and tolerability (pain) were monitored through 24 hours with corresponding acceptability questionnaires administered through 72 hours. WI (n = 205) automatically inserted the needle, delivered 5 mL ± 5% in 5.42 minutes (SD 0.74) and retracted. Depots were entirely (93.2%) or predominantly (5.4%) localized within the target subcutaneous tissue. Slight to moderate wheals (63.9%) and erythema (75.1%) were observed with ≥ 50% resolution within 30-60 minutes. Subject pain (100 mm Visual Analog Scale) peaked mid-injection (mean 9.1 mm, SD 13.4) and rapidly resolved within 30 minutes (mean 0.4 mm, SD 2.6). Subjects' peak pain (≥ 90.2%), injection site appearance (≥ 92.2%) and injector wear, size, and removal (≥ 92.1%) were acceptable (Likert responses) with 100% likely to use the injector if prescribed. Injection site preference was divided between none (46%), abdomen (25%), or thigh (26.9%). The investigational WI successfully delivered 5 mL viscous subcutaneous injections. Tissue effects and pain were transient, well-tolerated and acceptable. Neither injection site, movement or subject age affected injector functional performance or subject pain and acceptability.


Assuntos
Reação no Local da Injeção/diagnóstico , Injeções Subcutâneas/instrumentação , Dor/diagnóstico , Dispositivos Eletrônicos Vestíveis , Adolescente , Adulto , Idoso , Produtos Biológicos/administração & dosagem , Doença Crônica/tratamento farmacológico , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Reação no Local da Injeção/etiologia , Injeções Subcutâneas/efeitos adversos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Medição da Dor/estatística & dados numéricos , Adulto Jovem
4.
Int J Radiat Oncol Biol Phys ; 72(2): 597-604, 2008 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-18793963

RESUMO

PURPOSE: Report the results of using a permanently implantable dosimeter in radiation therapy: determine specific adverse events, degree of migration, and acquire dose measurements during treatment to determine difference between expected and measured dose. METHODS AND MATERIALS: The Dose Verification System is a wireless, permanently implantable metal-oxide semiconductor field-effect transistor dosimeter using a bidirectional antenna for power and data transfer. The study cohort includes 36 breast (33 patients received two devices) and 29 prostate (21 patients received two devices) cancer patients. A total of 1,783 and 1,749 daily dose measurements were obtained on breast and prostate patients, respectively. The measurements were compared with the planned expected dose. Biweekly computed tomography scans were obtained to evaluate migration and the National Cancer Institute's Common Toxicity Criteria, version 3, was used to evaluate adverse events. RESULTS: Only Grade I/II adverse events of pain and bleeding were noted. There were only four instances of dosimeter migration of >5 mm from known factors. A deviation of > or =7% in cumulative dose was noted in 7 of 36 (19%) for breast cancer patients. In prostate cancer patients, a > or =7% deviation was noted in 6 of 29 (21%) and 8 of 19 (42%) during initial and boost irradiation, respectively. The two patterns of dose deviation were random and systematic. Some causes for these differences could involve organ movement, patient movement, or treatment plan considerations. CONCLUSIONS: The Dose Verification System was not associated with significant adverse events or migration. The dosimeter can measure dose in situ on a daily basis. The accuracy and utility of the dose verification system complements current image-guided radiation therapy and intensity-modulated radiation therapy techniques.


Assuntos
Neoplasias da Mama/radioterapia , Neoplasias da Próstata/radioterapia , Neoplasias da Mama/diagnóstico por imagem , Desenho de Equipamento , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Humanos , Masculino , Mamografia , Movimento , Projetos Piloto , Neoplasias da Próstata/diagnóstico por imagem , Próteses e Implantes/efeitos adversos , Radiometria/instrumentação , Radiometria/métodos , Dosagem Radioterapêutica